Atmospheric Profiling

Atmospheric Profile System

LGR's system for atmospheric profile studies is very simple and cost effective. Such system compliments existing weather stations or eddy covariance sites and can be used under most environmental or weather conditions. Here is how it works:

  • Choose the trace gas analyzer such as the Ultraportable Greenhouse (CH4/CO2/H2O) Gas Analyzer
  • Connect the Multiport Inlet Unit to the analyzer
  • Connect tubing from the Multiport Inlet Unit to the desired sampling location
  • Power the system with a user-supplied power source

Advantages:

  • No data logger needed
  • No programming
  • Control your system through the internet
  • Monitor multiple trace gases

You can expand the system by adding a 3-D sonic anemometer at one or all inlets and a weather station if one is needed to record simple weather parameters. Please contact LGR with your questions at sales@lgrinc.com.

Request a Quote

1. Choose an Analyzer:
All LGR analyzers include: Internal software for full system control (GUI) and fast data analysis in real time (no licenses required); User Manual (in English); Remote access and control capability via the Internet (via remote desktop share); Certificate of Compliance that guarantees performance specifications; power cable; LGR technical support (via email/phone); and one-year warranty per LGR warranty policy.

Model 911-0010 Greenhouse Gas Analyzer - Simultaneous measurements of methane, carbon dioxide, and water vapor mole fractions (concentrations) continuously in flowing gas samples. System includes all software for analysis and an internal vacuum pump for 10-seconds pumpover time. Provided with the analyzer (at no extra cost):
(1) Software for system control (GUI) and fast data analysis (no licenses required)
(1) User Manual (in English)
(1) Remote access and control capability via the internet
(1) Certificate of Compliance that guarantees performance specifications
(1) Power Cable
(1) LGR technical support (via email/phone)
(1) One year warranty per LGR warranty policy

Model 915-0011 Ultraportable Greenhouse Gas Analyzer - 18.5" × 14" × 7" compact, crushproof package that weighs 15 kg. Operates directly on DC battery or AC power. Gas flow response time (1/e) with standard internal vacuum pump is 8 seconds.

2. Select Gas Input Option:

908-0003-9001 Multiport Inlet Unit - External hardware (includes 16 solenoid valves) and internal software package which enables fully integrated, programmable selection from up to 16 separate sources.

908-0003-9002 Multiport Inlet Unit - External hardware (includes 8 solenoid valves) and internal software package which enables fully integrated, programmable selection from up to 8 separate sources.

3. Select Additional Options:

908-0001-9017 Solid State Hard Drive - Upgrade of standard hard drive to 64 GB solid state hard drive. Recommended for applications where instrument may experience extreme vibration during use.

Extended Measurement Range - Extends the operational measurement range of methane measurements to 0-10% mole fraction in air. No external dilution is required for concentrations in this range.

904-0002 Data Logging Software - Simultaneously records the serial (RS-232) data outputs from multiple LGR analyzers and from other instruments, including Global Positioning System (GPS) devices, and sonic anemometers, into a single data file with a common time stamp. This allows users to easily synchronize, tabulate and graphically present and correlate historical data from several instruments with local GPS coordinates. Requires external Windows computer (laptop or desktop).

915-9001 Wireless User Interface - Apple iPad with WiFi router provides full instrument control and provides touch-screen video display, keyboard and mouse.

915-9002 Wireless User Interface - Google Nexus 7 with WiFi router provides full instrument control and provides touch-screen video display, keyboard and mouse.

Secondary AC-DC Power Supply

Battery Hook-Up Kit - Connections for operation on AC power, DC (battery) power, automobile power

Portable Filter, Fuse and Plug Kits - particle filter and additional fuses

DC Power Case for Ultraportable Analyzer use only - holds battery size: 8.2"x7.7"x5.1" or smaller and includes all battery terminal connections with ring lugs for 1/4-20 or 6mm screws, 2x automotive DC socket outputs - cigarette lighter style; battery not included due to shipping constraints - for customers outside the continental US

DC Power Case for Ultraportable Analyzer use only - holds battery size: 8.2"x7.7"x5.1" or smaller and includes all battery terminal connections with ring lugs for 1/4-20 or 6mm screws, 2x automotive DC socket outputs - cigarette lighter style; with 40Ah LiFePO4 battery included - for customers in the continental US

Backpack Harness for Ultraportable Analyzer

Service Kit - includes a rebuild kit for internal pump, mirror cleaning kit, and 32GB solid state hard drive.

Service Kit - includes a rebuild kit for internal pump, mirror cleaning kit, and 64GB solid state hard drive.

RM Young Model 81000V 3D Sonic Anemometer - a 3-axis, no-moving-parts wind sensor with four synchronized voltage input channels and serial output. It features durable corrosion-resistant construction with 3 opposing pairs of ultrasonic transducers supported by stainless steel members. Each sonic anemometer is individually wind-tunnel calibrated.

Climatronics AIO Compact Weather Sensor

Hemisphere GPS model R330 Series DGPS Receiver

Extended Warranty - Extends the standard one-year warranty of one Analyzer to a total of three years.